U.S.A. And CANADA
Purpose, function
Seals the atmosphere side of the charcoal canister during EVAP leak check monitoring.
Construction
Included in the charcoal canister.

The CV solenoid valve is consists of O-rings.

Operation
According to the control signal from the PCM, the coil is energized and the plunger opens/closes the CV solenoid valve.

Fail-safe
Function not equipped.
Canister Vent (Cv) Solenoid Valve Removal/Installation
Catalytic ConverterNeutral Switch Removal/Installation [C66 M R]
1. Disconnect the negative battery cable..
2. Remove the air cleaner component. (ex: air cleaner, air hose).
3. Remove in the order indicated in the table.
4. Install in the reverse order of removal.
1
Neutral switch connector
2
Neutral ...
Steering Gear And Linkage Disassembly
CAUTION:
To prevent damage to the steering gear, secure it to the vise using a copper
plate or clean cloth.
1. Disassemble in the order indicated in the figure.
1
Dust cover
2
O-ring
3
Tie-rod end ...
Shift Position Indicator Light [Fw6 A EL, Fw6 Ax EL]
Purpose/Function
The shift position indicator light indicates the selector lever position.
Construction
The shift position indicator light is built into the instrument cluster.
Operation
The TCM sends a shift position indicator light illumination request signal ...