U.S.A. And CANADA
Purpose, function
Seals the atmosphere side of the charcoal canister during EVAP leak check monitoring.
Construction
Included in the charcoal canister.

The CV solenoid valve is consists of O-rings.

Operation
According to the control signal from the PCM, the coil is energized and the plunger opens/closes the CV solenoid valve.

Fail-safe
Function not equipped.
Canister Vent (Cv) Solenoid Valve Removal/Installation
Catalytic ConverterClock Input/Output Check Mode
Activation procedure
Inspection
NOTE:
The clock input/output check mode is displayed in the following order and
returning to the previous screen is impossible.
If you want to check All LCD illuminated or Check code 1 or 2 after Check
code 6 is displayed, activate the inpu ...
Oil Cooler [Fw6 A EL, Fw6 Ax EL]
Purpose/Function
The oil cooler constantly maintains maximum ATF performance in the transaxle
by maintaining an optimum ATF temperature which has the effect of achieving
reduced fuel consumption.
Construction/Operation
The oil cooler performs the following operations accord ...
High Pressure Fuel Pump
Purpose, Function
Applies pressure to fuel sent from the fuel pump equipped on the fuel tank,
and then pumps it to the fuel delivery pipe.
Fuel is sectioned and pumped by the up and down movement of the piston caused
by the rotation of the cam installed to the rear end of the ex ...