1. Verify that the gap and height difference between the fuel-filler lid and body.
2. Loosen the bolts and adjust the fuel-filler lid.
a: 1.7—3.7 mm {0.07—0.14 in}
b: ?0.5—1.5 mm {?0.01—0.05 in}
3. Tighten the bolts..
Camshaft Position (CMP) Sensor Removal/Installation
CAUTION:
When replacing the CMP sensor, make sure there is no foreign material on
it such as metal shavings. If it is installed with foreign material, the sensor
output signal will malfunction resulting from fluctuation in magnetic flux and
cause a deterioration in engine control.
...
Driveline/Axle SST
Front and Rear Axle
49 T028 3A0
Ball joint puller set
49 T028 301
Dust boot installer
49 U034 204
Dust boot installer
49 W032 310
Support block
—
— ...
Electric Variable Valve Timing Actuator
Purpose, Function
The electric variable valve timing actuator changes the phases of the intake
camshaft relative to the crankshaft. As a result, the open/close period of the
intake valve is changed, optimized valve timing in accordance with driving conditions
is realized, output is i ...