Chevrolet Spark manuals

Mazda CX-5 Service & Repair Manual: Air Intake Actuator [Full Auto Air Conditioner]

Mazda CX-5 Service & Repair Manual / Engine / Intake / Air Intake Actuator [Full Auto Air Conditioner]

Purpose

Function


Construction

Operation

1. The climate control unit outputs a motor drive signal to the air intake actuator based on the air intake mode determined by the air intake control.

2. When the air intake actuator moves to FRESH or REC, the motor locks.

3. When the motor locks and is under excessive load, the current value flowing from the climate control unit increases more than the specification (lock current).

4. When the lock current is detected, the climate control unit stops the motor drive signal to the air intake actuator.


Fail-safe

Air Intake Actuator Removal/Installation [Manual Air Conditioner]
1. Disconnect the negative battery cable.. 2. Remove the glove compartment.. 3. Disconnect the air intake actuator connector. 4. Remove the screw, then remove the air intake actuator. 5. I ...

Air Intake Actuator [Manual Air Conditioner]
Purpose The air intake actuator moves the air intake door in the blower unit to switch the air intake port. Function The air intake actuator drives the motor based on the signal ...

Other materials:

Evaporative Emission (Evap) Control System
Purpose, Outline Prevents release of evaporative gas into the atmosphere. The intake manifold vacuum introduces evaporative gas to the intake manifold via the charcoal canister and the purge solenoid valve. System Diagram U.S.A. and CANADA Except U.S.A. and CANADA ...

Liftgate Opener System
Outline A liftgate opener system has been adopted in which the liftgate can be opened just by pressing the liftgate opener switch. The rear body control module (RBCM) performs liftgate opener system fail-safe.. Function When the liftgate opener switch is pressed, the l ...

Pressure Control Valve Inspection [Skyactiv G 2.0]
1. Remove the pressure control valve assembly.. CAUTION: Do not apply a pressure 36 kPa {0.37 kgf/cm2, 5.2 psi} or more. Doing so will damage the pressure control valve and evaporative hose. 2. Apply a pressure of 36 kPa {0.37 kgf/cm2, 5.2 psi} to port A. 3. Verify that ther ...

© 2016-2025 Copyright www.mcx5.org