Purpose
The instrument cluster operation record stores the record of the illumination or flashing of the warning light.
Function
The operation record is stored by the instrument cluster and displayed using the Mazda Modular Diagnostic System (M-MDS).
The instrument cluster stores the following when any of the warning lights illuminates or flashes.
Time and date
Control module which sent warning light illumination/flash request
Battery voltage
Construction
Based on the stored record, the instrument cluster displays the following operation record on the M-MDS screen.

Operation
When the instrument cluster receives a CAN signal or a warning light illumination/flash request signal sent from each switch, it controls the warning light to illuminate/flash and stores the operation record at the same time.
Fail-safe
Function not equipped.
Instrument Cluster Inspection
Instrument Cluster Operation RecordCooling Fan Relay
Purpose, Function
The cooling fan relay operates by receiving the signal from the PCM to supply
power to the cooling fan motor.
Construction
The cooling fan relay is installed on the relay and fuse block.
Operation
The contact point is on when the battery vo ...
PID/Data Monitor Inspection [Blind Spot Monitoring (Bsm)]
1. Connect the M-MDS to the DLC-2.
2. After the vehicle is identified, select the following items from the initialization
screen of the M-MDS.
a. Select “DataLogger”.
b. Select “Modules”.
c. Select “BSML” or “BSMR”.
3. Select the applicable PID from the PID table.
4. Ve ...
Refrigerant Pressure Check
NOTE:
Measure the refrigerant pressure after approx.10 min have elapsed
from engine start.
1. Install the manifold gauge..
2. Start the engine and warm it up.
3. Set the fan speed MAX HI.
4. Turn the A/C switch on.
5. Set to RECIRCULATE mode.
6. Set the temperature control ...