Outline
The A/C unit which integrates the cooling and heater units has been adopted.
Construction
The A/C unit consists of the following parts.

Operation
Air Mix Door Operation
The air mix door, installed in the A/C unit, controls HOT or COLD position, depending on the position of the temperature control dial. As a result, airflow distribution changes, and the airflow temperature is controlled.

Airflow Mode Door Operation
The airflow mode doors move to VENT, BI-LEVEL, HEAT, DEF/HEAT, or DEFROSTER position, depending on the position of the airflow mode selector dial. As a result, airflow mode changes.

Fail-safe
Function not equipped.
A/C Cut Off Control [Skyactiv G 2.0]
A/C Unit Disassembly/AssemblyThrottle Position (TP) Sensor
Purpose/Function
Detects the throttle valve opening/closing condition, which operates in accordance
with the accelerator pedal operation, as basic information for mainly determining
the fuel injection amount.
Detects the throttle valve opening/closing condition, which operates i ...
Oil Cooler [Fw6 A EL, Fw6 Ax EL]
Purpose/Function
The oil cooler constantly maintains maximum ATF performance in the transaxle
by maintaining an optimum ATF temperature which has the effect of achieving
reduced fuel consumption.
Construction/Operation
The oil cooler performs the following operations accord ...
Pressure Control Valve Inspection [Skyactiv G 2.0]
1. Remove the pressure control valve assembly..
CAUTION:
Do not apply a pressure 36 kPa {0.37 kgf/cm2, 5.2 psi} or more. Doing so
will damage the pressure control valve and evaporative hose.
2. Apply a pressure of 36 kPa {0.37 kgf/cm2, 5.2 psi} to port A.
3. Verify that ther ...