Outline
The A/C unit which integrates the cooling and heater units has been adopted.
Construction
The A/C unit consists of the following parts.

Operation
Air Mix Door Operation
The air mix door, installed in the A/C unit, controls HOT or COLD position, depending on the position of the temperature control dial. As a result, airflow distribution changes, and the airflow temperature is controlled.

Airflow Mode Door Operation
The airflow mode doors move to VENT, BI-LEVEL, HEAT, DEF/HEAT, or DEFROSTER position, depending on the position of the airflow mode selector dial. As a result, airflow mode changes.

Fail-safe
Function not equipped.
A/C Cut Off Control [Skyactiv G 2.0]
A/C Unit Disassembly/AssemblyOil Control Valve (OCV) Inspection [Skyactiv G 2.0]
Coil Resistance Inspection
1. Disconnect the negative battery cable..
2. Remove the plug hole plate..
3. Disconnect the OCV connector.
4. Measure the resistance between terminals A and B using an ohmmeter.
OCV coil resistance
6.9—7.5 ohms [20°C {68°F}]
If ...
Speaker [Without Bose®]
Purpose
Converts the audio signal from the audio unit to sound.
Function
Full-range speakers, which can output wide-range sound from low to high frequency,
have been adopted.
Specification
Item
Front door speaker
Rear speaker ...
Splash Shield Removal/Installation
Front
Front splash shield No.1
1. Set the mudguard aside..
2. Remove fasteners A.
3. Remove the front splash shield No.1.
4. Install in the reverse order of removal.
Front splash shield No.2
1. Remove screw B.
2. Remove fasteners C.
3. Remove the front splash shield No.2.
4. ...