Rear Upper Arm Removal/Installation [Awd]
Wheel Alignment Pre InspectionResistor [Manual Air Conditioner]
Purpose
The resistor controls the blower motor rotation speed.
Function
The resistor controls the supply voltage to the blower motor according to
the fan switch operation, and adjusts the fan rotation speed (airflow volume).
Construction
The resistor is installed ...
Buckle Switch Inspection
Driver-side
1. Switch the ignition to off.
2. Disconnect the negative battery cable and wait for 1 min or more..
3. Remove the front seat..
4. Remove the front buckle..
5. Inspect for continuity between the buckle switch terminals using a tester.
If not as indicated in the tab ...
Manual Type
Control Switches
Temperature control dial
This dial controls temperature. Turn it clockwise for hot and counterclockwise
for cold.
NOTE
When the mode is set to or with the fan control dial in a position other than
0 and the temperature control dial in the maximum cold position, the air int ...